mechanical seal drawing pdf

The stationary part of the seal is fitted to the pump housing with a static seal this may be sealed with an o-ring or gasket clamped between the stationary portion and the pump housing. L1 Seal Head Operation Height OP.


Mechanical Seal An Overview Sciencedirect Topics

External reservoir pressurized above seal chamber pressure providing barrier fluid to mechanical.

. Mechanical Seals For Pumps How Mechanical Seals Work. Seal faces can be lubricated by the process fluid or with double mechanical seals by a proper auxiliary fluid see chapter relevant to configurations. 442Split Mechanical Seal Technical Data 442 SPLIT MECHANICAL SEAL EQUIPMENT BOLT PATTERNS 2 BOLTS 2 BOLTS 3 BOLTS 4 BOLTS All Other Shaft Sizes 2 BOLTS 3 BOLTS 4 BOLTS 4 BOLTS Shaft Sizes.

D3 Counterbore or Seat OD. 5 ALPHA ALPHA Hydraulic force generated by. Mechanical seal hardware represents the components required to apply mechanical tension to the rotating and stationary seal faces.

The seals are arranged by shaft size from smallest to largest. Therefore standard mechanical seals are used only for a pressure up to 10 bar. 512 Make sure you have all the spare parts to be able to service the machine before proceeding.

From small elastomer bellows seals used in millions of domestic water pumps to double mechanical seals that ensure maximum sealing safety and large highly customized dry-running gas seals for mission critical high speed turbo compressors John Crane has the right product for any. Seal all seams with ul 181 mastic. 13There are several types of such drawings.

Refer to page 2 through 6 to identify the seal. In the critical sealing of boiler feed and boiler circulation water Flowserve continues to innovate new technology. Jensen Type F Mechanical Seal Parts Drawing No.

12 Design An essential mechanical seal contains three sealing points. And sealed to smacna class c. Two seals per cartridge assembly with a chamber between.

8 O Ring. The seal between the rotating 3 and stationary faces 1. HT L2 Seat Thickness DMR.

To quickly design detailed drawings for parts or seals. 9 Install the mechanical seal in the pump. Fig5 THE FUNDAMENTALS 3 Fig.

All symbols and abbreviations shown. The product pressure acts additional to the spring on the rotating seal part. You can measure according to the Drawing Codes for the correct.

The seal between the rotating member and shaft or shaft sleeve 4. This is due to various reasons. Remove the seal drawing from packaging.

Lower than seal pressure. TEMPERATURE-60F TO 400F -50C TO 204C PRESSURE 400 psi 27 bar SPEED 5000 fpm 25 ms 1 T he Liberator I cartridge seal patented incorporates advanced seal design features. Identify the correct replacement seal.

To install a seal the pump would have to be taken off-line and disassembled. Mechanical seals in which there is provided a system of. In this case two mechanical seals are arranged in series.

A connect to plan 75 B connect to plan 76 N 2 C A N 2 A Device to be located below pump shaft Used for hot applications or where products have low pressure and are harmfulhazardous. Drawings of related components may be given on the same sheet. Two seals per cartridge assembly with a chamber between the two seals at a LOWER pressure than the pump seal chamber.

A mechanical seal has 4 main sealing points indicated by orange circles as per Figure 3. Mechanical seals are designed to overcome these drawbacks. Sparingly lubricate the pump shaft with John Crane Silicone O-ring.

Mixer Model Serial Number Item Number 4 O Ring. With this level of local customer focus the Quick Response Centers are ready to respond to. EPDM Neoprene Nitrile Chemraz Kalrez and Viton are available.

Make sure the seal matches the unit where installation will take place. 511 Make sure that the mechanical seal is corresponding to the assembly drawing. Buffer gas used to dilute seal leakage.

Part Name and Part Drawing Number. A Place gland with stationary seal face and gasket on the pump shaft. Drawingdetail number sheet number re.

O-RINGS Aflas is standard. Please Note that the number of springs. 12 represents an example of a production drawing.

Drawing Codes D1 Shaft Size D2 Seal Head OD. If you are unable to identify the seal it will be necessary for you to measure the old seal for correct identification. May use a liquid buffer gas buffer or no buffer fluid.

The scope of our mechanical seal product range far exceeds any other seal manufacturer. Rotary O-ring 6. Will vary depending upon seal bore.

Shall be constructed to 12 wg. 123 Assembly drawing A drawing that shows the various parts of a machine in their correct working locations is an assembly drawing as shown in fig. ROTATING SEAL FACE Alpha sintered Silicon Carbide.

1625 to 4750 40 mm to 120 mm 15 5 11 12 4 3 2 10 16 1. It is also influenced by. With a lower k value the safety against thermal overload will increase but the mechanical seal may also lift off more easily.

Mechanical seal selection The spring is in the product. For higher pressures balanced mechanical seals are used. Socket Head Cap Screw 3.

Packing Although mechanical seals had been around for many decades by 1955 industry had converted only a small percentage of pumps from packing to mechanical seals. Has also been referred to as a tandemseal. Set screw the rotary unit to the shaft sleeve if seal is supplied with holding clips remove at this time.

An stable and complete layer of lubrication greatly affects the performance and the life of a mechanical seal. Installing the Seal 1. Seal are selected based on fluid compatibility temperature elastomeric qualities and depending on the type and design of the seal they may perform in either a dynamic or static state.

Unlike an O-Ring seal the hydraulic diameter of a bellows seal is not a fixed geometric value. Item 13 Wearing Parts. 2m171 1 drawing note reference ie notes by symbol miscellaneous drawingdetail reference abbreviations general notes mechanical symbols and abbreviations note.

B Slide rotary unit on shaft sleeve and set the back of the rotary unit on the second scribe line as determined in step 8. Tures and seal face features to achieve long mechanical seal life. Verify that the direction of shaft rotation shown on the seal layout drawing matches the actual rotation of the pump shaft.

TM Mechanical Seals Selecting a replacement Mechanical Seal 861 Cranberry Court Oakville ON L6L 6J7 Phone. This is known as the primary seal. Mechanical seal and is defined as In practice k values are selected between 065 and 12.

The seal between the stationary member 1 and stuffing box face ie.


Sigma Seals Products


Component In Mechanical Face Seal 1 Download Scientific Diagram


Sigma Seals Products


Mechanical Seal An Overview Sciencedirect Topics


Double Seal For Ss Reactor And Double Mechanical Seal For Hydrogenerator Exporter


Mechanical Seal With Metal Bellows And Plan 66a Solve Process Pump Sealing Problems Sciencedirect


Pdf Centrifugal Pump Mechanical Seal And Bearing Reliability Optimization Semantic Scholar


Double Seal For Glass Lined Reactor And Double Mechanical Seal For Anfd

0 comments

Post a Comment